螺柱焊現(xiàn)場故障代碼與報(bào)警

              2022-10-28 16:39:00
              孫輝
              原創(chuàng)
              7135

              welding is not permitted.

              解釋: 啟動(dòng)焊接信號(hào)后無接觸信號(hào),導(dǎo)致無法焊接

              Cause: ? No stud in collet.

              原因:  夾套里沒有焊釘

              ? Feeder without weld studs.

              送料器里沒有焊釘

              ? Stabilizer incorrectly set or contaminated.

              支撐腳或噴嘴調(diào)整不當(dāng)或太臟

              ? Weld circuit interrupted.

              焊接回路中斷

              ? Weld head fault (i.e. weld head got jammed).

              焊頭故障(例如:焊頭被卡住了)

              ? Collet defective.

              夾持器損壞了

              Remedy: ? Remove loading fault.

              措施: 排除送釘故障

              ? Check adjusting of stabilizer.

              檢查支撐腳或噴嘴的調(diào)整狀態(tài)

              ? Check welding circuit.

              檢查焊接回路

              ? Stud feeding.

              送一次釘

              ? Repeat weld cycle.

              重復(fù)一次焊接

              ? Replace collet.

              更換夾持器

              ? Notify service engineer!

              專業(yè)人員處理

                                                                                                                                      

              Fault 3: “Weld tool not in back position“

              故障 3 :焊頭沒有在焊接位置

              Explanation: Proximity switch for back position not configured, defective or power supply missing.

              解釋:焊接位置的接近開關(guān)沒有被蓋住或接近開關(guān)被損壞或者沒有電壓

              Cause: ? Drop in compressed-air supply.

              原因: 壓縮空氣供應(yīng)氣壓不足

              ? Cable package defective.

              管線總成損壞

              ? Monitoring time after welding was exceeded.

              焊接之后的檢測時(shí)間超差

              ? Weld head defective.

              焊頭損壞

              ? Feeder defective.

              送料器損壞

              ? Collet welded to work surface.

              把夾持器焊在工件表面了

              Remedy: ? Check compressed air.

              措施:  檢查壓縮空氣供應(yīng)裝置

              ? Check cable package.

              檢查管線總成

              ? Check weld head - slide rail motion.

              檢查焊頭運(yùn)動(dòng)滑軌

              ? Check or replace weld head.

              檢查或更換焊頭

              ? Check feeder.

              檢查送料器

              ? Check feeder fuses F1-F3.

              檢查送料器保險(xiǎn)絲F1-F3

              ? Reset fault.

              故障復(fù)位

              ? Replace collet.

              更換夾持器

              ? Notify service engineer!

              專業(yè)人員處理

                                                                               

              Fault 5: “Weld procedure sequence fault“

              故障 5 :焊接程序順序故障

              Explanation: Due to a malfunction the weld sequence is not terminated correctly.

              解釋:由于一個(gè)錯(cuò)誤功能使焊接過程沒有按照程序進(jìn)行到底

              Cause: ? Feeder or SMPS malfunction.

              原因:  送料器或電源故障

              Remedy: ? Reset fault.

              措施:  故障復(fù)位

              ? Check welding (if necessary repeat welding).

              檢查焊接(重新焊接)

              ? Notify service engineer!

              專業(yè)人員處理

                                                                                                                                      

              Fault 6: “Program no selected“

              故障 6 缺少程序

              Explanation: The weld unit does not detect any program number.

              解釋: 焊接單元不識(shí)別程序號(hào)碼

              Cause: ? Program no. is 0.

              原因: 程序號(hào)碼為0

              ? Transfer signal has not been set.

              沒有設(shè)置接受信號(hào)

              ? Data line defective.

              數(shù)據(jù)線被損壞了

              Remedy: ? Customer interface (or interface program) must be verified.

              措施: 檢查用戶接口(或接口程序)是否編寫

              ? Notify service engineer!

              專業(yè)人員處理

                                                                                                                                     

              Fault 7: “Program not active“

              故障 7 程序沒有激活

              Explanation: The selected weld program is not active and therefore cannot be executed.

              解釋: 由于被選擇的焊接程序沒有被激活,因此無法實(shí)施焊接

              Cause: ? Weld unit incorrectly programmed.

              原因: 焊接單元程序編寫錯(cuò)誤

              ? Fault customer control.

              用戶控制端錯(cuò)誤

              ? Data line defective.

              數(shù)據(jù)線被損壞了

              Remedy: ? Check weld program and activate or select an active weld program.

              措施:  檢查焊接程序并激活或者選擇一個(gè)已經(jīng)激活的程序

              ? Notify service engineer!

              專業(yè)人員處理

                                                                  

              Fault 13: “SMPS: Lift fault“

              故障 13   電源:沒有拉弧

              Explanation: Weld unit is unable to identify lift via measurement lines.

              解釋:焊機(jī)通過它的測量線不能確定拉弧過程

              Cause: ? Incorrectly sequence of lift movement.

              原因: 拉弧過程的順序不正確

              ? Weld conditions prohibit lift.

              焊接條件阻礙了拉弧

              ? Cable package defective.

              管線總成損壞

              ? Weld head defective.

              焊頭被損壞

              ? Defective feeder.

              送料器被損壞

              ? Internal process cycle fault.

              設(shè)備內(nèi)部運(yùn)行故障

              Remedy: ? Check weld conditions.

              措施: 檢查焊接條件

              ? Check weld head.

              檢查焊頭

              ? Check feeder.

              檢查送料器

              ? Stud feeding.

              送一次釘

              ? Check feeder connection.

              檢查送料器連接線

              ? Repeat weld cycle.

              重復(fù)一次焊接

              ? Forced WC.

              啟動(dòng)焊接完成信號(hào)

              ? Notify service engineer!

              專業(yè)人員處理

                                                                         

              Fault 15: “Drop down timeout“

              故障 15 下落時(shí)間超時(shí)

              Explanation: Max. drop time was exceeded and welding was stopped.

              解釋: 下落時(shí)間超出最大允許值,焊接被中斷

              Cause: ? Air gap incorrectly adjusted.

              原因: 間隙調(diào)整錯(cuò)誤

              ? Weld circuit resistance too high.

              焊接回路電阻過高

              ? Measurement line-ground missing.

              沒有連接地線測量線

              ? SKK / PK defective.

              自動(dòng)焊頭或焊槍損壞

              Remedy: ? Reset fault.

              措施: 故障復(fù)位

              ? check measurement line (if necessary, reduce weld circuit resistance)

              檢查測量線(降低焊接回路電阻值)

              ? Check setting of SKK- / PK.

              檢查自動(dòng)焊頭或焊槍狀態(tài)

              ? Notify service engineer!

              專業(yè)人員處理

                                                                                                                                     

              Fault 16: “Open circuit, no arc“

              故障 16 空載焊接

              Explanation: Extinguishing of the arc during weld, resp. the weld current is below I =80A.

              解釋: 焊接過程中拉弧被斷開,或焊接回路電流小于80A

              Cause: ? Air gap too large.

              原因: 間隙過大

              ? Gun was removed at the beginning of the weld.

              焊槍在開始焊接時(shí)被提起

              ? Extremely impure work surface.

              焊接表面油污太多

              ? Fault SMPS.

              電源故障

              Remedy: ? Repeat weld cycle.

              措施: 重復(fù)一次焊接

              ? Stud feeding.

              送一次釘

              ? Check adjusting of the weld gun.

              檢查焊槍的調(diào)整

              ? Check welding conditions.

              檢查焊接條件

              ? Check work piece conditions.

              檢查工件表面

              ? Notify service engineer!

              專業(yè)人員處理

                                                                                                                                  

              Fault 17: “Measurement line broken“

              故障 17 測量線中斷

              Explanation: Measurement line signal not any longer detected.

              解釋: 測量線信號(hào)沒有被捕捉到

              Cause: ? Measurement line broken or incorrectly connected.

              原因: 測量線損壞或連接錯(cuò)誤

              ? Reversed measurement line-ground and measurement line.

              地線測量線和測量線接反了

              ? SOW power failure.

              和工件的接觸電壓中斷

              ? Weld line interrupted.

              焊接電纜中斷

              Remedy: ? Check fuses on front panel.

              措施: 檢查面板上的保險(xiǎn)絲

              ? Reset fault.

              故障復(fù)位

              ? Check welding cable.

              檢查焊接線

              ? Check measuring line.

              檢查測量線

              ? Check ground- measurement line

              檢查地線測量線.

              ? Check feeder fuses.

              檢查送料器的保險(xiǎn)絲

              ? Notify service engineer!

              專業(yè)人員處理

                                                                      

              Fault 23: “Handgun sequence not followed“

              故障 23 手槍焊接啟動(dòng)條件

              Explanation: Correct sequence when welding with a gun (PK/PLM) was not observed.

              解釋:  在用手槍焊接時(shí)沒有遵守正確的焊接順序

              Cause: ? Angularity switch by-passed or incorrectly adjusted.

              原因: 角度開關(guān)被橋接或調(diào)整錯(cuò)誤

              ? Trigger start by-passed.

              啟動(dòng)開關(guān)被橋接

              ? Correct sequence "SOW-ANG-START" not observed.

              沒有遵守SOW(接觸信號(hào))-WS(角度開關(guān))- START(焊接)的焊接順序

              Remedy: ? Observe sequence "SOW-ANG-START".

              措施:  遵守SOW(接觸信號(hào))-WS(角度開關(guān))- START(焊接)的焊接順序

              ? Check PK for correct setting of angularity.

              檢查角度開關(guān)的調(diào)整情況

              ? Release trigger and restart.

              松開啟動(dòng)開關(guān)并重新啟動(dòng)

              ? Notify service engineer!

              專業(yè)人員處理

                                                  

              Fault 25: “Wrong stud loaded“

              故障 25 焊釘輸送錯(cuò)誤

              Explanation: The supplied stud is not the specified stud required by unit control.

              解釋: 所提供的焊釘不是焊機(jī)指定的焊釘

              Cause: ? The weld unit identified an incorrect stud in the weld head via the lift measuring system or the stud verification test.

              原因:  焊機(jī)只識(shí)別通過拉弧測量系統(tǒng)或者通過焊釘檢驗(yàn)的焊釘?shù)暮割^   

              Remedy: ? Reset fault.

              措施:  故障復(fù)位

              ? Repeat stud feeding.

              重新送一次釘

              ? Verify correct stud length in the feeder.

              檢驗(yàn)送料器里焊釘?shù)拈L度

              ? Check programming.

              檢查程序

                                                                                                                                    

              Fault 30: “Weld out of tolerance”

              故障 30 焊接參數(shù)超差

              Explanation: Collective fault for the exceeded tolerances.

              解釋:  一般性超差

              Cause: ? The following tolerances are out of parameter: weld current, weld time, Vp, Vw, Pen, Varc peak, Varc drop or weld energy.

              原因: 超出公差的參數(shù):焊接電流,焊接時(shí)間,拉弧電壓,焊接電壓,焊接深度,電壓峰值,電壓降或焊接能量

              ? Defective SMPS or welding tool.

              電源或焊接工具損壞

              Remedy: ? Reset fault.

              措施: 故障復(fù)位

              ? Check tolerances.

              檢查公差設(shè)定值

              ? Check weld circuit and weld conditions.

              檢查焊接電流和焊接條件

              ? Check SMPS and welding tool.

              檢查電源和焊接工具

                                                 

              Fault 100: “Feeder: No power to aux. supply“

              故障 100 送料器:沒有電壓

              Explanation: The feeder identifies no voltage supply.

              解釋: 送料器沒有電壓供應(yīng)

              Cause: ? Defective feeder fuse.

              原因: 送料器保險(xiǎn)絲損壞

              ? Defective feeder.

              送料器損壞

              Remedy: ? Replace feeder fuse.

              措施: 更換送料器保險(xiǎn)絲

              ? Check feeder.

              檢查送料器

              ? Notify service engineer!

              專業(yè)人員處理

                                                   

              ault 102: “Feeder: Feed rail not filled in time“

              故障 102 送料器:焊釘傳送錯(cuò)誤

              Explanation: Filling of the rail way is not ensured.

              解釋: 焊釘傳送過程中出現(xiàn)故障

              Cause: ? Sufficient stud level in the separating drum not reached.

              原因: 焊釘卡在了滑道上

              ? Mechanical defect of the escapement rails

              滑道上有機(jī)械故障

              ? Wrong adjusting on the stud inlet dish.

              焊釘口調(diào)整錯(cuò)誤

              ? Wrong adjusted or defective proximity switch "Min".

              最小接近開關(guān)調(diào)整錯(cuò)誤或損壞

              Remedy: ? Check adjusting.

              措施: 檢查送料器調(diào)整

              ? Replenish weld studs.

              加滿焊釘

              ? Remove blockage.

              清除滑道上焊釘

              ? Adjust proximity switch or/and replace.

              調(diào)整接近開關(guān)或更換

              ? Notify service engineer!

              專業(yè)人員處理

                                                     

              Fault 106: “Feeder: Feed tube locking switch open“

              故障 106 送料器:送料管被鎖緊

              Explanation: The signal for feed hose locking at the stud feeder is not configured.

              解釋: 送料器鎖緊信號(hào)開關(guān)沒有被蓋上

              Cause: ? Feed tube not connected (gun).

              原因: 送料管沒有連接

              ? No bridge for feed tube locking (head).

              送料管鎖緊開關(guān)沒有連上

              ? Defective cable package.

              管線總成損壞

              ? Defective fuse F5 on PCB ETF CPU E510.

              中央處理器E510電路板保險(xiǎn)絲F5損壞

              Remedy: ? Connecting feed tube.

              措施: 連接送料管

              ? Check locking switch.

              檢查緊鎖開關(guān)

              ? Check cable package.

              檢查管線總成

              ? Replace fuse.

              更換保險(xiǎn)絲

              ? Notify service engineer!

              專業(yè)人員處理

                                                 

              Fault 109: “Feeder: Feed cycle timeout“

              故障 109 送料器:送料循環(huán)超時(shí)

              Explanation: The weld unit indicates an incorrectly performed feed cycle.

              解釋: 焊機(jī)顯示一個(gè)錯(cuò)誤的送料循環(huán)

              Cause: ? The feeder does not terminate a feed cycle in the maximum

              monitoring time.

              原因: 送料器沒有把送料循環(huán)鎖定在最大的監(jiān)控時(shí)間內(nèi)

              Remedy: ? Check feeder.

              措施: 檢查送料器

              ? Repeat stud feeding.

              重復(fù)一次焊接

              ? Notify service engineer!

              專業(yè)人員處理

                                                           

              Fault 118: “Feeder: +5V Keypad not detected“

              故障 118 :送料器:控制面板沒有 +5V 電壓供應(yīng)

              Explanation: The voltage supply 5V for the keypad communication is missing.

              解釋: 控制面板通信的+5V電壓沒有

              Cause: ? Defective fuse F3 on PCB ETF CPU E510.

              原因: 中央處理器E510電路板保險(xiǎn)絲F3損壞

              ? Defective optocoupler on the PCB ETF CPU E510.

              E510電路板上的光耦合器損壞

              Remedy: ? Replace fuse.

              措施: 更換保險(xiǎn)絲

              ? Replace PCB ETF CPU E510.

              更換E510電路板

              ? Notify service engineer!

              專業(yè)人員處理

                                                                                                                                  

              Fault 119: “Feeder: LM / Solenoid under voltage“

              故障 119 送料器:自動(dòng)焊槍 / 電磁閥不足

              Explanation: The voltage supply for the linear motor / solenoid is less than 90 Volt

              解釋: 直流電機(jī)/電磁閥的供電電壓低于90V

              Cause: ? Defective fuse F2 on ETF PCB Amplifier E 512.

              原因: 放大器E512     電路板保險(xiǎn)絲F2損壞

              ? Defective ETF PCB amplifier E 512.

              放大器E512電路板損壞

              Remedy: ? Replace fuse F2.

              措施: 更換保險(xiǎn)絲F2

              ? Replace ETF PCB Amplifier E 512.

              更換放大器E512電路板

              ? Notify service engineer!

              專業(yè)人員處理

                                                         

              Fault 121: “Feeder: LM/Solenoid over voltage“

              故障 121 :送料器:自動(dòng)焊槍 / 電磁閥電壓超出

              Explanation: The voltage supply for pcb E 512 is out of the tolerance range.

              解釋: 給電路板E512供電的電壓超出公差范圍

              Cause: ? Transformer wrong connected.

              原因: 轉(zhuǎn)換器連接錯(cuò)誤

              ? Defective transformer.

              轉(zhuǎn)換器損壞

              Remedy: ? Check connection transformer.

              措施: 檢查轉(zhuǎn)換器連接

              ? Exchange transformer.

              更換轉(zhuǎn)換器

              ? Notify service engineer!

              專業(yè)人員處理

                                                                                                                                  

              Fault 122: “LM/Solenoid not detected“

              故障 122   自動(dòng)焊槍 / 電磁閥故障

              Explanation: The connected welding tool on the feeder has not linear motor or solenoid.

              解釋: 同送料器連接的焊接工具不是直線電機(jī)或電磁閥

              Cause: ? No welding tool connected.

              原因: 沒有連接焊接工具

              ? Defective cable package.

              管線總成損壞

              Remedy: ? Connect weld tool.

              措施: 連接焊接工具

              ? Check cable package.

              檢查管線總成

              ? Notify service engineer!

              專業(yè)人員處理

                                        

              Fault 167: “Feeder: +5V not detected“

              故障 167 送料器: +5V 檢測電壓缺失

              Explanation: The voltage supply +5V for the measurement stretch length is missing.

              解釋: 測量拉伸長度的+5V電壓缺失

              Cause: ? Defective cable package.

              原因: 管線總成損壞

              ? Defective PCB in the weld head.

              焊頭里的電路板損壞

              ? Defective optocoupler on the ETF CPU E510.

              E510里的光耦合器損壞

              Remedy: ? Check cable package.

              措施: 檢查管線總成

              ? Check PCB in the weld head.

              檢查焊頭里的電路板

              ? Replace PCB ETF CPU E510.

              更換E510電路板

              ? Notify service engineer!

              專業(yè)人員處理

              評(píng)論列表
              2024-02-27 17:37:20
              電源故障異常是什么
              1/1
              發(fā)表評(píng)論
              拆信。(打一城市名)?(答案:開封)
              評(píng)論通過審核后顯示。
              聯(lián)系我們
              聯(lián)系人: 韓玉琦
              電話: 0755-26013200/26013464
              傳真: 0755-26013188
              Email: saw@sawchina.cn
              QQ: 2280915288
              微信: 18682260315
              旺旺: szhbkj
              地址: 東莞市鳳崗鎮(zhèn)東深路鳳崗段206號(hào)天安深創(chuàng)谷W2棟誠信大廈21樓
              • 在線客服
              • 關(guān)注微信
                • 業(yè)務(wù)咨詢
                • 人才招聘
                • 售后咨詢
              • 掃一掃關(guān)注微信
                鴻栢科技
                深圳市鴻栢科技實(shí)業(yè)有限公司
              移動(dòng)訪問
              99久久久久国产视频,国产免费变态视频网站。,无毒中文字幕无码高清,久久九九aⅴ免费精品